What's new
What's new

Measured Thermal Expansion of a 1.25" dia by 10" long Steel Bar in Response to Bare Hand Contact

dgfoster

Diamond
Joined
Jun 14, 2008
Location
Bellingham, WA
This thread began as a response to questions/suggestions regarding my new right angle plate design. The concerns raised were based on sound theory but how that theory actually applied to the real world was a question I wanted to look at in a limited but geramine way.

Here are a couple pics of the plate milled.
1674102913948.jpeg
1674102620169.jpeg
I just recently milled my angle plate allowing me to set one up and answer the question raised as to how much casual hand contact with the strut would cause distortion of the plate. I wanted to be able to make a quantitative measurement of distortion rather than just blindly follow the warning to not touch the strut with a bare hand or, as others suggested, to make leather, plastic, or wood covers for the strut to insulate it.

Here are pics of the setup used.
1674100201062-jpeg.384414


You can see the base is a 12X18" granite surface plate. I 3-pointed the angle plate on the surface plate using small lightly lapped 2mm nuts. The setup is reasonably stable allowing grasping the strut without changing the reading by an interpolated readout a millionth. While grasping the strut the reading does change by a millionth to 1.5 millionths, but returns to zero on release. Lightly tapping on the base of the angle plate makes the needle jump but it does not remain deviated. Those observations indicated to me that the setup is robust enough to make reasonable measurements.

1674100238865-jpeg.384415


So, grasping the strut with an uninsulated hand does cause an easily seen and steady deflection of the face of the plate. It takes 25 to 30 seconds of steady grasp to deflect the face .0001" Upon release,the face slowly returns to its pre-contact location though that could take 20 minutes or so.

I'll be doing some more observation tomorrow though I repeated the above half a dozen times while doing some other work in the shop today.

For those doing super fussy work and wanting to avoid virtually all hand-contact thermal distortion, a simple garden glove or leather glove or equivalejnt will do the trick, at least on this casting. There was virtually no heat conduction with either a common leather work glove or a medium-weight rubber-palmed garden glove.

Because it takes so long to dissipate heat in the strut, a user should keep in mind that hand contacts are somewhat cumulative. In other words, holding onto the strut uninsulated for 10 second exposures repeated, say, five times over a few minutes would cause about 2 tenths deflection. Those same contacts spread over a couple hours would be of much less consequence.

So, I am not planning on covering up the strut or changing the design some other way. I will be casting another one (and a 36" camelback) in the morning if it does not rain.

Denis

I will be putting this measuring device, generously loaned to me by CarbideBob, to use more in the future looking at camelbacks (which I expect to be more sensitive) and other devices as my interest is piqued. It would be great to see other folks contribute some measurements of thermal distortion that they might make
 

Attachments

  • 1674100201062.jpeg
    1674100201062.jpeg
    349.2 KB · Views: 0
  • 1674100238865.jpeg
    1674100238865.jpeg
    278.6 KB · Views: 0
Last edited:








 
Top