Mazak Integrex 200SY mk 1 (Fusion 640MT) Cycle start without Y at home

ViktorS

Aluminum
Joined
Apr 26, 2021
Hello,

I'm having an issue (or a nuisance really) that I can't get cycle start when Y axis is not at home.
Sometimes when doing some manual stuff it would be really handy to be able to, i.e. when doing a MDI with a part-off tool that have a small Y adjustment to be on center line.
Is there any way to disable this check, or is there a reason for this requirement?

Thank you!
 

noname777

Cast Iron
Joined
Aug 24, 2018
Location
NSW , Australia
I can bet all my pocket money for this week that there is a parameter inside PLC to disable CYCLE START when Y axis isnt at home. Something like this. This is taken from INT 300 SY mk1 book
 

Attachments

  • Untitled3.jpg
    Untitled3.jpg
    154.2 KB · Views: 6

ViktorS

Aluminum
Joined
Apr 26, 2021
Well that didn't work unfortunatly.
That parameter was already set to on, but turning it off rendered no difference.
 

noname777

Cast Iron
Joined
Aug 24, 2018
Location
NSW , Australia
What is actually happening when you are trying to START CYCLE with Y not at home? IS there any alarm? Anything on the screen like a message/warning?
 








 
Top