We have a Puma 12L that sometimes loses it's sync. It has a 10TF control.
These are my notes for fixing it:
Do make sure that if the turret indexes when you fire the switch YOU ARE CLEAR!
------------------------------
IF THE PUMA 12L TURRET LOSES IT'S SYNC WITH THE CONTROL.
REMOVE COVER AT BACK OF TURRET
PRESS NC/PC BUTTON (TOP LEFT OF CONTROL PANEL)
PRESS PCPRM SOFT KEY
PRESS COUNTR SOFT KEY
COUNTER 01 IS SHOWING THE TURRET NUMBER THAT THE CONTROL THINKS IS CURRENT.
KEEP CLEAR OF THE TURRET !!!!!!
----------------------
SOLVED
I got to the counter parameter by using the above method except for removing the turret cover.
Once I verified that the COUNTER 1 parameter was changing with the turret position, I went back and set the PWE (Parameter Write Enable)
to 1 by:
MDI
Press SETTING soft Key once, then SETTING Soft key again
Arrow up once to 8000.0 (PWE)
Press Right arrow to cursor to PWE
Input 1 (Soft Key) alm will light
Then I went back to the PC side by:
PRESS NC/PC BUTTON (TOP LEFT OF CONTROL PANEL)
PRESS PCPRM SOFT KEY
PRESS COUNTR SOFT KEY
cursor over to the far right parameter and set it to whatever the turret position was at (mine was rotated to 1) I used the input key under the FANUC number keypad. (Doing this kept me from having to operate the machine switch behind the turret).
Repeat the procedure to set PWE back to 0.
Hope this helps and thanks for everyone's help.