Hello, I have a Sodick A320D EX21 that I've had for over 20 years but is having an issue. When you try to run at max settings I get a short circuit error, if I lower the settings and keep Amps to about 8 or lower it will run all day no worries. As soon as I increase power it will SC again. Sodick have suggested a few fixes like changing main power cables to tank and also cables to T&B heads but nothing has worked. They have also tried changing some boards but no difference, I think they are out of ideas so was wondering if anyone has ever seen this problem before?
Regards Glenn.
 

jkss

Plastic
Joined
Jan 18, 2023
Hello, I have a Sodick A320D EX21 that I've had for over 20 years but is having an issue. When you try to run at max settings I get a short circuit error, if I lower the settings and keep Amps to about 8 or lower it will run all day no worries. As soon as I increase power it will SC again. Sodick have suggested a few fixes like changing main power cables to tank and also cables to T&B heads but nothing has worked. They have also tried changing some boards but no difference, I think they are out of ideas so was wondering if anyone has ever seen this problem before?
Regards Glenn.
Sir i am jk from india I know this problem solution is ur mechine power generator is have unproper cooling plz check cooling system
 








 